| item | unit | parameters |
| routine | ||
| Rated voltage | kV | 12 |
| Rated frequency | HZ | 50 |
| Power frequency withstand voltage | kV/min | 42/48 |
| Lightning impulse voltage | kV | 75/85 |
| Duration of ignition | S | ≥0.5 |
| Primary component protection class (metering cabinet | IP67 | |
| Except) | IP4X | |
| Cabinet protection level | IP2X | |
|
Class of compartment protection Operating supply voltage |
V | DC24、48、110、220 |
| AC110、220 | ||
| Bus system | A | 630(1250) |
| Rated current | kA/s | 20/4(25/4) |
| Rated short-time withstand current | kA | 50(63) |
| Rated peak withstand current | kA | 50 |
| Rated peak withstand current | ||
| Load switching unit | A | 630 |
| Rated current | kA | 50 |
| Rated short-circuit closing current | kA/s | 20/4 |
| Rated short-time withstand current | time | |
| Load switch mechanical life | time | E3 |
| Load switch electrical life | PC | ≤5 |
| Partial discharge | ||
| Circuit breaker unit | A | 630(1250) |
| Rated current | kA | 20(25) |
| item | unit | parameters |
| Rated short-circuit closing current | kA | 50(63) |
| Rated short-time withstand current | kA/S | 20/4(25/4) |
| Mechanical life of circuit breaker | time | 20000 |
| Circuit breaker electrical life | time | E2 |
| Rated operating sequence | 0-0.3s-CO-180s-CO | |
| Partial discharge | PC | ≤5 |
| Load switch - | ||
| Fuse combination electrical unit | A | 200 |
| Rated current (Max.) | kA | 31.5 |
| Rated short-circuit breaking current | kA | 80 |
| Rated short-circuit closing current | PC | 3150 |
| Partial discharge | ||
| Disconnecting switch | A | 630/1250 |
| Rated current | kA | 20/25 |
| Rated short-time withstand current | S | 4 |
| Rated short duration | kA | 50/63 |
| Rated peak withstand current | time | 3000 |
| Mechanical life | ||
| Ground switch | A | 630/1250 |
| Rated current | kA | 20/25 |
| Rated short-time withstand current | S | 4 |
| Rated short duration | kA | 50/63 |
| Rated peak withstand current | kA | 50 |
| Rated short circuit closing current (peak) | time | 2 |
| Rated short circuit closing current number | time | 3000 |
PT cabinet with load switch (fully insulated type)
Standard configuration
◆630A insulated bus ◆ Load grounding switch
◆ Load grounding switch operating mechanism
◆ Load/ground switch
◆ The outlet bushing is located in the front horizontal position, and the 630A front cable head is connected
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Solid insulated voltage transformer
◆ Elbow joint (with cable)
◆ Voltage transformer protection breaker
◆ Ground busbar
◆ Meet the five anti-interlock
Optional configuration ◆ Heater ◆ Voltmeter
Breaker cabinet
Standard configuration
◆630, 1250A insulated bus
◆ Vacuum circuit breaker
◆ Vacuum circuit breaker operating mechanism
◆ Isolated ground switch
◆ Isolation/grounding switch operating mechanism
◆ Circuit breaker and ground switch mechanical interlock
◆ Circuit breaker and ground switch have independent position display
◆ The outlet bushing is located in the front horizontal position, and the front cable head is connected
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Ground busbar
◆ Microcomputer protection device
◆ Meet the five anti-interlock
Optional configuration
◆ Auxiliary contact ◆ Program lock
◆ Heater
◆ Rear arrester
◆ Rear cable head
◆ Incoming line live ground lock
◆ Ground fault indicator
◆ Bushing type current transformer and ammeter, active power meter, reactive power meter
Circuit breaker busbar
Standard configuration
◆630A, 1250A insulated bus
◆ Vacuum circuit breaker
◆ Vacuum circuit breaker operating mechanism
◆ Isolation/grounding switch
◆ Isolation/grounding switch operating mechanism
◆ Circuit breaker and ground switch mechanical interlock
◆ Circuit breaker and ground switch have independent position display
◆ The outlet sleeve is located in the front horizontal position, and the front cable head (with cable)
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Ground busbar
◆ Microcomputer protection device
◆ Meet the five anti-interlock
Optional configuration
◆ Auxiliary contact ◆ Program lock
◆ Heater
◆ Rear arrester
◆ Rear cable head
◆ Incoming line live ground lock
◆ Ground fault indicator
◆ Bushing type current transformer and ammeter, active power meter, reactive power meter
Hoist tank
Standard configuration
◆630A, 1250A insulated bus
◆ The outlet sleeve is located in the front horizontal position, and the front cable head (with cable)
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Ground busbar
Optional configuration ◆ Heater
◆ Rear arrester
◆ Rear cable head
◆ Ground fault indicator
◆ Bushing type current transformer and ammeter, active power meter, reactive power meter
Inspection before use: Before the ring network unit is used, the following checks must be carried out for personal and equipment safety
Check whether the main circuit and the ground circuit are correctly connected.
Check whether the mechanical interlock is correct and reliable.
Check whether the load switch and ground switch in the ring network unit are operated flexibly and correctly.
Check the high voltage cable connection is correct and reliable.
certificates
◇Q/GDW730-2012 "12kV solid insulation ring network cabinet technical conditions"
◇GB1984 "AC high voltage Circuit breaker"
◇GB38043.6kV-40kV "AC high voltage load switch"
◇GB1958 "AC High voltage isolation switch and ground switch"
◇GB4208 "Shell protection level IP Code"
◇GB 16926 High voltage AC load switch-fuse combination appliance
◇GB/T15166.2 High voltage AC circuit breaker - Part 2: Current limiting circuit
◇GB/T7354 "Partial Discharge Measurement"
◇GB/T11022 "High Voltage Switchgear and control equipment standards common technical conditions"
◇GB3906 "3.6-40.5kV AC metal enclosed switchgear and control equipment"
1、What is your packaging standard?
Usually we use standard foam and carton packaging. If you have special requirements, we can also meet your requirements.
2、Why do you buy from us instead of other suppliers?
More than 10 years experience in design and manufacture of high voltage switchgear accessories. It is one of the largest star suppliers in the industry, and has won international and domestic praise, and has been shortlisted for the National Grid.
3、What services can we provide?
Acceptable delivery methods :FOB,CFR,CIF,EXW,FCA, Express;
Accepted payment currency: USD, EUR, GBP, RMB;
Payment methods accepted: Wire transfer, L/C, MoneyGram, credit card, Western Union, cash;
Languages: English, Chinese
Address
Sulu Avenue, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province, China
Tel